Supply: check valveRecall 08V-263 · Kme vehicles

KOVATCH MOBILE EQUIPMENT recall 08V-263 covers 122 Kme vehicles for a supply: check valve problem, reported to NHTSA on June 12, 2008.

–
Vehicles repairedNo manufacturer report yet
Vehicles affected1222 models
ReportedJun 12, 2008Owners notified Oct 3, 2007
Complaints since0Same system, after the recall

Source: NHTSA recall 08V263000 and manufacturer quarterly reports. Started by an NHTSA defect investigation.

What's wrong

The problem

KME IS RECALLING 122 MY 2006-2007 PREDATOR AND SEVERE SERVICE PUMPER, AERIAL AND TDA FIRE TRUCKS. A CHECK VALVE WAS OMITTED FROM THE SECONDARY SUPPLY PORT OF THE BENDIX SR-7 SPRING BRAKE MODULATING VALVE.

The risk

AS A RESULT, AN AIR LEAK IN THE SECONDARY OR PRIMARY SYSTEM MAY RESULT IN THE PARK BRAKES INADVERTENTLY APPLYING, INCREASING THE RISK OF A CRASH.

What to do

The fix

DEALERS WILL ADD A CHECK VALVE TO THE SECONDARY SUPPLY PORT OF THE SR-7 SPRING BRAKE MODULATING VALVE AND WILL ALSO REPAIR THE SR-7 VALVE BY APPLYING A CHECK VALVE REPAIR KIT AS REQUIRED FOR THE BENDIX SAFETY RECALL (PLEASE SEE 07E037). THE RECALL BEGAN ON OCTOBER 3, 2007. KME HAS COMPLETED 68 OF THE 123 TRUCKS AND WILL COMPLETE THE REPAIR WORK BY SEPTEMBER 30, 2008 FREE OF CHARGE. OWNERS MAY CONTACT KME AT 1-570-669-5154.

CUSTOMERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO HTTP://WWW.SAFERCAR.GOV.

Recall repairs are free. Confirm whether this recall is open on your vehicle by entering its VIN at nhtsa.gov/recalls.

2 models

Vehicles in this recall

Built from January 1, 2006 to August 31, 2007. Not every vehicle in these model years is included; check by VIN.

Background

The investigation behind this recall

  1. BENDIX SR-7 SPRING BRAKE MOD. VALVESEQ08006 · closed Aug 27, 2008
    NHTSA