Equipment adaptive/mobilityRecall 16V-001 · 2006–2013 Aev Ambulance Wheelchair Van

Halcore Group, Inc. recall 16V-001 covers 9 2006–2013 Aev Ambulance Wheelchair Van for a equipment adaptive/mobility problem, reported to NHTSA on January 4, 2016.

–
Vehicles repairedNo manufacturer report yet
Vehicles affected91 model
ReportedJan 4, 2016Owners notified Jan 13, 2016
Complaints since0Same system, after the recall

Source: NHTSA recall 16V001000 and manufacturer quarterly reports. Started by an NHTSA defect investigation.

What's wrong

The problem

Halcore Group, Inc. (Halcore) is recalling certain model year 2006-2013 American Emergency Vehicles (AEV) Ambulance Wheelchair Vans manufactured January 2, 2006 to March 15, 2013, equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon Corporation. The affected lifts are equipped with folding link arms that may have pivot holes that are too big, allowing the bearings to move out of position.

The risk

If the bearings move out of position, the stowed platform may have excessive movement resulting in failure of the platform mounting. This failure could cause the wheel chair lift platform to fall out of the vehicle when the doors are opened, increasing the risk of injury for the lift operator.

What to do

The fix

Halcore will notify the owners, and Ricon dealers will inspect the link arms for damage or for displaced bearings. The platform will be inspected for cracks. Any damaged parts will be replaced, free of charge. The recall began on January 13, 2016. Owners may contact Ricon Customer Service at 1-800-322-2884 or AEV customer service at 1-800-374-9749. Halcore's number for this recall is 15E-068.

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

Recall repairs are free. Confirm whether this recall is open on your vehicle by entering its VIN at nhtsa.gov/recalls.

1 model

Vehicles in this recall

Built from January 2, 2006 to March 15, 2013. Not every vehicle in these model years is included; check by VIN.

Background

The investigation behind this recall

  1. Wheelchair lift platform failureRQ15002 · closed Oct 16, 2015