Tank assembly: filler pipe and capRecall 82V-041 · 1982 Lincoln Continental

FORD MOTOR COMPANY recall 82V-041 covers 15,988 1982 Lincoln Continental for a tank assembly: filler pipe and cap problem, reported to NHTSA on April 27, 1982.

–
Vehicles repairedNo manufacturer report yet
Vehicles affected15,9881 model
ReportedApr 27, 1982Owners notified May 26, 1982
Complaints since0Same system, after the recall

Source: NHTSA recall 82V041000 and manufacturer quarterly reports. Started by the manufacturer.

What's wrong

The problem

THE INVOLVED VEHICLES MAY HAVE BEEN PRODUCED WITH AN INADEQUATE SEAL BETWEEN THE FUEL FILLER PIPE-HOUSING ASSEMBLY AND THE FUEL FILLER OPENING-COLLAR ASSEMBLY. TWO ATTACHING SCREWS AT THE BOTTOM OF THIS JOINT WERE OMITTED DURING ASSEMBLY. IT IS POSSIBLE THAT A SMALL QUANTITY OF OVERFLOW FUEL COULD LEAK INTO THE RIGHT REAR FENDER WELL BEHIND THE LUGGAGE COMPARTMENT TRIM PANEL IF FUEL "SPIT-BACK" OR OVERFILLING WERE TO OCCUR DURING REFUELING.

What to do

The fix

DEALER WILL INSTALL THE TWO MISSING FASTENERS AND A LOWER FLANGE REINFORCEMENT AT NO COST TO OWNER.

VEHICLE DESCRIPTION: PASSENGER VEHICLES.SYSTEM: FUEL; FUEL FILLER.CONSEQUENCES OF DEFECT: IF FUEL LEAKAGE WERE TO TAKE PLACE, IT IS POSSIBLE THATA FUEL AND AIR MIXTURE IN THE FENDER WELL COULD BE IGNITED BY NEARBY ELECTRICALCOMPONENTS CAUSING VEHICLE DAMAGE AND SERIOUS PERSONAL INJURY.

Recall repairs are free. Confirm whether this recall is open on your vehicle by entering its VIN at nhtsa.gov/recalls.

1 model

Vehicles in this recall

Built from August 1, 1981 to March 1, 1982. Not every vehicle in these model years is included; check by VIN.